香港奥德赛创科技有限公司

主营:深圳压力传感器厂家,深圳称重传感器供应商,深圳压力传感器销售

免费店铺在线升级

联系方式

进口角度传感器MVDIO32-CO-PCB

2019-12-06 10:52:01  335次浏览 次浏览
价 格:面议

Digital I/O module. 16 digital inputs (24V, PNP/NPN specified on ordering), 16 digital outputs (24V, 3A max). CAN bus and RS-232 interfaces. Fullfils CIA's device profile for IO devices (DS401).Connections with spring-loaded connectors or PG outlets or MIL- connectors in case that the module is housed in cast-aluminum IP65 rated casing. Power supply 9...28 V. MVDIO32-CO-PCB

MVDIO32-CO-H-MIL

MVDIO32-CO-H-PG

技术参数:

Type Digital I/O module

Digital inputs 16 (24V, polarity PNP/NPN can be selected in groups of 4)

Digital outputs 16 (24V, PNP, 3A / channel)

Interfaces RS-232 CAN (CANopen)

Main processor Motorola MC68HC08AZ60 (8-bit)

CAN bus transceiver Philips TJA1050

Operating voltage 9 - 30V (compliant with ISO/DTR 7637 class 4)

Operating temperature range -40...+85°C (-40... + 185°F)

Dimensions 100x160x100 mm

Protection Class IP65 (IP67 available on request)

Product description

The basic configuration of the module includes 16 PNP inputs and 16 PNP outputs. The output types are fixed, but the input types can be selected in groups of 4 (in ordering). The outputs have a current limitation of 3A / channel, and the outputs are also protected against short-circuit and overtemperature.

The I/O module is designed for harsh environments. The module is mounted in an IP65-protected case, and IP67 rating is also available on request. The standard module has spring-loaded connectors inside the module case, which require no seperate external connectors for the wiring. Module can also be supplied with customer-specific connectors.

Power supply for the module can be on the range 9 - 30V. The module is protected against reverse battery connection, overvoltage, and load-dump situations. The power supply is tested against the very strict ISO/DTR 7637 class 4 standard.

I/O can be controlled either using RS-232 or CAN buses. A connector for RS-232 or CAN (or both) of desired type can be mounted on the case on request. The module is available with CANopen protocol. The CAN bus node id is changed through the RS-232 interface using normal terminal software. CAN bus termination can be switched on by using a jumper.

Applications

Typical applications include for example:

• mobile applications, vehicles, work machines

• cranes, elevators

• robotics, material handling machines

网友评论
0条评论 0人参与
最新评论
  • 暂无评论,沙发等着你!
百业店铺 更多 >

特别提醒:本页面所展现的公司、产品及其它相关信息,均由用户自行发布。
购买相关产品时务必先行确认商家资质、产品质量以及比较产品价格,慎重作出个人的独立判断,谨防欺诈行为。

回到顶部